Arrangement 8 (Single Inlet Single Width)
Methane extraction fan in a coal mine, supplying methane to a co-generation plant. Fitted with vibration monitoring equipment ë1,100mm diameter 132kW 3,600rpm.
- Coupling drive
- Tunnel bearings
- 12mm casing
- Anti static
- Operation VIV and VSD
- Vibration/temperature monitoring points
- Repressurisation seal
- Bearing and motor pads machined after welding
- Covered hand holes to lower noise levels